String wound filter manufacturer · Friendswood, Texas (409) 370-3162 llove@fluid-filtration.com

Filter media · Code P, FP

Polypropylene string wound filter cartridges

Polypropylene is the workhorse media for water and chemical service. It holds up to concentrated acids and alkalies, oxidizers and other corrosive fluids, and comes in both an economy grade and an FDA grade.

Max media temperature
180°F
Media codes
P, FP
Micron ratings
0.5–200
FDA grade
Available

Where polypropylene works

  • Concentrated acids and alkalies
  • Oxidizers
  • Corrosive fluids and gases
  • Process and utility water
  • Food and beverage service (FDA grade, code FP)

Media codes

CodeMedia
PPolypropylene
FPPolypropylene, FDA grade

Choosing a core

A polypropylene core is the natural match, keeping the whole cartridge in polypropylene. Choose a stainless core when you need extra strength.

CodeCoreTypical serviceMax operating temp with polypropyleneFDA material
PPolypropyleneWater and corrosives180°FYes
TTin-plated steelOils and solvents180°FNo
S304 stainless steelDiluted acids180°FYes
A316 stainless steelStrong acids180°FYes

Example part numbers

Part numbers read Media – Micron – Diameter – Length – Core – End cap. Standard lengths run 9¾" to 40" and our standard outside diameter is 2½" (code R).

Part numberDescription
P5R10PPolypropylene, 5 micron, 2½" O.D., 10", polypropylene coreQuote
FP1R20PFDA polypropylene, 1 micron, 2½" O.D., 20", polypropylene coreQuote
P10R30SPolypropylene, 10 micron, 2½" O.D., 30", 304 stainless coreQuote

Configure a polypropylene cartridge

Pick the micron rating, length, core and end cap, then print a spec sheet or send us a quote request.

Build a part number Make a spec sheet Request a quote

Other filter media

Polyester
Up to 350°F
Cotton
Up to 300°F
Rayon
Up to 300°F
Nylon
Up to 300°F
Fiberglass
Up to 750°F